نتایج جستجو برای: retrofitting, steel buildings slit steel shear wall, damper device, non

تعداد نتایج: 2228427  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان 1390

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

Journal: :journal of structural engineering and geo-techniques 2015
leila shahryari mahdi esfandiari

the steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...

Leila Shahryari Mahdi Esfandiari

The steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. Composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...

Journal: :journal of the structural engineering and geotechnics 0
ali molaei manzar faculty of mechanics, islamic azad university, takestan branch, takestan, iran hassan aghabarati department of civil and architectural engineering, islamic azad university, qazvin branch, iran

dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. these walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. in this research intermediate dual system of steel moment frame was chosen with int...

Ali Molaei Manzar Hassan Aghabarati,

Dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. These walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. In this research intermediate dual system of steel moment frame was chosen with int...

Journal: :مهندسی سازه 0
ارژنگ صادقی رضا باقر ملکی

during the last few decades, steel shear walls have been adopted as efficient lateral resisting systems for high rise structures and numerous researches have been conducted on their static and dynamic behavior. steel shear walls have been utilized for retrofitting existing structures, as well as in design of new buildings in japan and usa. in this research, we have focused on the optimization o...

Seismic rehabilitation provides existing buildings with more resistance to seismic activity, ground motion, or geotechnical failure due to earthquakes. Performance-based rehabilitation is a general concept through which the retrofitting criteria are defined regarding to performance objectives when the structural and nonstructural members are subject to different levels of earthquake hazards. In...

2016
Antonio Formisano Luca Lombardi Federico M. Mazzolani

Metal Plate Shear Walls (MPSWs) represent an effective, practical and economical system for the seismic protection of existing RC framed buildings. They consist of one or more metallic thin plates, bolted or welded to a stiff steel frame, which are installed in the bays of RC framed structures. A case study of an existing RC residential 5-storey building, designed between the ‘60s and ‘70s of t...

Journal: :journal of structural engineering and geo-techniques 2012
f. barati a. esfandiari

in this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. the finite element modeling technique (sap2000 software) is used for analysis. time history analyzing was done to achieve this purpose. for nonlinear dynamic analysis, the responses of ...

A. Esfandiari, F. Barati

In this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. Seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. The finite element modeling technique (SAP2000 Software) is used for analysis. Time History analyzing was done to achieve this purpose. For nonlinear dynamic analysis, the responses of ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید